Sales · Installation · Authorised service+421 905 455 357info@rkmedical.sk
MDC SV 05
Communication, nurse call and multimedia systemsZPT Vigantice

ZPT Vigantice MDC SV 05

MediCall nurse call system with a touchscreen display, visual call indication above room doors and the option of voice messages.

Price on requestQuote includes installation and training
Made to order
Request a quoteCall

About the device

The MDC SV05 nurse call system from the MediCall product range is designed for healthcare, social care facilities, sanatoriums, spa houses and similar settings. In addition to standard call signalling, the system can be extended with voice elements that allow one-way communication towards clients, i.e. central announcements. The system can operate as a single whole or, if required, can be divided at the press of a single button into separate subsystems that operate fully autonomously. This function is useful in all facilities that use temporary staff stations, for example during day shifts. It enables effective communication between staff and patients and allows the system to be extended with further elements and functions. The MDC SV05 system is a set of independent functional units and elements. All MediCall products are designed to meet the high demands of today's modern facilities, with an emphasis on convenience and ease of operation.

System components

21 components. The system is configured to order – please quote the catalogue number in your inquiry.

  • Main control unit SV05, wall-mounted 102301 HU-N – MDC SV 05
    102301

    SV05 main control unit, wall-mounted HU-N

    Dimensions: 86 mm x 150 mm x 26 mm

    • simple and clear operation
    • acoustic and visual signalling of individual calls
    • address of the calling location shown on the display
    • system programming and configuration
    • acceptance and cancellation of client calls
    • acceptance and cancellation of alarms
    • transmission of voice messages to the system (in the version with broadcast module)
    • colour graphic display
    • touchscreen display
  • Main control unit SV05, desktop 102361 HU-S – MDC SV 05
    102361

    SV05 main control unit, desktop HU-S

    Dimensions: 86 mm x 150 mm x 64 mm

    • simple and clear operation
    • acoustic and visual signalling of individual calls
    • address of the calling location shown on the display
    • system programming and configuration
    • acceptance and cancellation of client calls
    • acceptance and cancellation of alarms
    • transmission of voice messages to the system (in the version with broadcast module)
    • colour graphic display
    • touchscreen display
  • Patient socket 109202 ZU – MDC SV 05
    102380

    Distribution socket + cable ZR

    Dimensions: 86 mm x 86 mm x 26 mm

    • allows the desktop main control unit to be connected via a flexible lead (2 m)
    • mounted on the wall near the main control unit, on a KU 68 installation box in an installation frame
  • Main control unit SV05, wall-mounted 102301 HU-N – MDC SV 05
    102331

    Section control unit, wall-mounted SU-N

    Dimensions: 86 mm x 150 mm x 26 mm

    • acoustic and visual signalling of individual calls
    • address of the calling location shown on the display
    • decentralisation of the system into a pre-programmed subsystem
    • simple and clear operation
    • acceptance and cancellation of client calls
    • acceptance and cancellation of alarms
    • transmission of voice messages to the system
    • colour graphic display
    • touchscreen display
  • Signalling unit 109235 SIJ – MDC SV 05
    109235

    Signalling unit SIJ

    Dimensions: 86 mm x 86 mm x 26 mm

    • option of staff registration
    • option of connecting any number of subscriber sockets, emergency call buttons and pull cords
    • option of sending a client call
    • option of sending an alarm
    • transmission of acoustic signals when staff are registered
  • 102340

    Signalling unit with broadcast module SIJ-O

    Dimensions: 86 mm x 150 mm x 26 mm

    • option of staff registration
    • option of connecting any number of subscriber sockets, emergency call buttons and pull cords
    • option of sending a client call
    • option of sending an alarm
    • transmission of acoustic signals when staff are registered
    • transmission of central announcements from the main or section control unit
  • Signalling unit with display 109462 SIJ-D – MDC SV 05
    109462

    Signalling unit with display SIJ-D

    Dimensions: 86 mm x 150 mm x 26 mm

    • address of the calling location shown on the display
    • transmission of acoustic signals when staff are registered
    • option of connecting any number of subscriber sockets, emergency call buttons and pull cords
    • option of staff registration
    • option of sending an alarm
    • option of sending a client call
  • Entrance unit 102350 VJ – MDC SV 05
    102350

    Entrance unit VJ

    Dimensions: 86 mm x 150 mm x 26 mm

    • option of sending a request for a voice connection with staff
    • two-way voice connection with the main or section control unit
    • full replacement for a door entry intercom, including control of the associated electric lock
  • Sound sensor 109242 ZS – MDC SV 05
    109242

    Sound sensor ZS

    Dimensions: 86 mm x 86 mm x 26 mm

    • sends a visual and acoustic signal to staff when the set maximum noise level in the room is exceeded
    • the element is installed as a peripheral part of the addressable elements
  • Patient socket 109202 ZU – MDC SV 05
    109202

    Subscriber socket ZU

    Dimensions: 86 mm x 86 mm x 26 mm

    • allows an emergency call cord to be connected
    • the element is installed as a peripheral part of the addressable elements
  • Patient socket with button 109532 ZU-T – MDC SV 05
    109532

    Subscriber socket with button ZU-T

    Dimensions: 86 mm x 86 mm x 26 mm

    • option of sending a client call
    • allows an emergency call cord to be connected
    • the element is installed as a peripheral part of the addressable elements
  • Emergency call cord 109172 VS-VN – MDC SV 05
    109172

    Emergency call cord VS-VN

    Dimensions: 40 mm x 84 mm x 26 mm

    • option of sending a client call
    • connects to the subscriber socket or the subscriber socket with button
  • Wireless button 109540 BT – MDC SV 05
    109540

    Wireless button BT

    Dimensions: 40 mm x 84 mm x 26 mm

    • used to initiate a client call wirelessly
    • the element is installed as a peripheral part of the addressable elements
  • Emergency call button 109352 TNV – MDC SV 05
    109352

    Emergency call button TNV

    Dimensions: 86 mm x 86 mm x 26 mm

    • option of sending a client call
    • the element is installed as a peripheral part of the addressable elements
  • Emergency call pull cord 109362 TANV – MDC SV 05
    109362

    Emergency call pull cord TANV

    Dimensions: 86 mm x 86 mm x 26 mm

    • option of sending a client call
    • the element is installed as a peripheral part of the addressable elements
  • Pneumatic emergency call switch socket 109382 ZPS – MDC SV 05
    109382

    Socket for pneumatic emergency call switch ZPS

    Dimensions: 86 mm x 86 mm x 26 mm

    • the element is installed as a peripheral part of the addressable elements
  • Pneumatic emergency call switch 109370 PS – MDC SV 05
    109370

    Pneumatic emergency call switch PS

    option of sending a client call

  • Indicator light 109390 SV – MDC SV 05
    109390

    Light SV

    Dimensions: 86 mm x 86 mm x 48 mm

    • visual signalling according to call type
  • Indicator light 109390 SV – MDC SV 05
    109490

    Directional light SV-S

    The directional light is designed for visual transmission of all calls from locations that are not in the direct line of sight of staff. Acoustic signalling is also a functional part of the element (optional function).

    • Dimensions: 86 mm x 86 mm x 48 mm
  • Call cord holder 102320 ZVS – MDC SV 05
    102320

    Call cord hanger ZVS

    Dimensions: 55 mm x 95 mm x 40 mm

    • used to hang the emergency call cord
  • Power supply 102260 NAP – MDC SV 05
    102260

    Power supply NAP

    A stand-alone unit connected on the input side to the mains distribution and on the output side to the supply line. This type of power supply is used when the number of addressable elements in the system does not exceed 100. Mains supply requirements – 1+N+PE 230V/50Hz. Mains supply lines must be protected by a separate 6A circuit breaker. Maximum power input 100VA.

    • Dimensions: 230 mm x 200 mm x 95 mm

More from Communication, nurse call and multimedia systems